FLIR AX8 thermal monitoring camera

Modern thermal image monitoring of important on-board equipment

The FLIR AX8 thermal monitoring camera watches critical equipment on your vessel, including engines, exhaust manifolds, and shaft bearings, to spot problems before you're stranded on the water. The AX8 integrates with Raymarine multifunction displays (MFDs) and sends audible and visual alerts when the temperature of machine parts rise above preset thresholds. Featuring FLIR’s MSX® imaging, which blends imagery from visible and thermal cameras, the FLIR AX8's detailed imagery is easier to understand.

State-of-the-art thermal monitoring of critical equipment onboard...

The FLIR AX8 thermal monitoring camera watches critical equipment on your vessel, including engines, exhaust manifolds, and shaft bearings, to spot problems before you're stranded on the water. The AX8 integrates with Raymarine multifunction displays (MFDs) and sends audible and visual alerts when the temperature of machine parts rise above preset thresholds. Featuring FLIR’s MSX® imaging, which blends imagery from visible and thermal cameras, the FLIR AX8's detailed imagery is easier to understand.

State-of-the-art thermal monitoring of critical equipment onboard.

  • Spot potential problems before they happen

    FLIR 's Exclusive Multi-Spectral Dynamic Imaging (MSX®) creates thermal imaging that is easier to understand.

  • Thermal Alarming and Visual Analysis

    Program specific areas to generate automated spot alarms when temperatures exceed pre-set thresholds.

  • Raymarine Integration

    View thermal, visible, and MSX video imagery on Raymarine LightHouse II™ MFDs.

Video

Specifications
General

Alarm Functions

Automatic alarms on any selected measurement function. A maximum of 5 alarms can be set

Alarm Output

Digital Out, store image, file sending (ftp), email (smtp), notification

Camera size (L x W x H)

54 x 25 x 79 mm (2.1 x 1 x 3.1 in.) w/o connectors; 54 x 25 x 95 mm (2.1 x 1 x 3.7 in.) w/ connectors

Color palettes

Color palettes (BW, BW inv, Iron, Rain)

Detector Type

Focal Plane Array (FPA) Uncooled Microbolometer

Field of View

48° x 37°

Packaging

Infrared camera with lens, printed documentation, user documentation CD-ROM, cooling/mounting plate, POE injector, Camera PoE Cable, Raymarine RayNet Ethernet cable

Packaging Size

210 x 142 x 70 mm (8.27 x 5.59 x 2.76 in.)

Set-up Commands

Data / Time, Temperature °C/°F

Spectral Range

7.3-13µm

Web interface

Yes

Connections & Communications

Ethernet

Control, result and image

Ethernet Connector Type

M12 8-pin X-coded

Ethernet Power

Power over Ehternet, PoE IEEE 802.3as class 0

Ethernet Protocols

Ehternet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, SFTP, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour)

Ethernet Standard

IEEE 802.3

Ethernet Type

100 Mbps

Ethernet Video Streaming

Yes

Storage Media

Built-in memory for internal storage

Environmental

Atmospheric transmission correction

Automatic, based on inputs for distance, atmospheric temperature and relative humidity

Bump

25 g (IEC 60068-2-29) / 2 g (IEC 60068-2-6)

EMC

EN 61000-6-2:2001 (Immunity) | EN 61000-6-3:2001 (Emission) | FCC 47 CFR Part 15 Class B (Emission) | EN 60945:2002 | EN60945 (Electromagnetic Compliance)

Emissivity Correction

Variable from 0.01 to 1.0

Encapsulation

IP67 (IEC 60529)

Humidity (Operating and Storage)

IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)/ 2 cycles

Operating Temperature Range

0°C to +50°C (32°F to +122°F)

Storage Temperature Range

–40°C to +70°C (–40°F to +158°F) IEC 68-2-1 and IEC 68-2-2

Vibration

2 g (IEC 60068-2-6); EN 60945:2002

Ignition Protection

EN 28845:1993

Marine Imaging & Optical

Automatic Image Adjustment

Continuous

Focus

Fixed

Image Modes

Thermal, Visual, MSX (IR-image with enhanced detail presentation)

Image Streaming Formats

Motion JPEG, MPEG, H.264

Image Streaming Resolution

640x480

IR Resolution

80x60 pixels

Measurement & Analysis

Accuracy

+/-2°C (+/-3.6°F) or +/-2% of reading (+10 to +100C@+10 to +35amb)

Area

6 Boxes with max. / min. / average

External Optics & Windows Correction

Automatic, based on input of optics / window transmission and temperature

Measurement Corrections

Global Object Parameters

Measurement Presets

Yes

Object Temperature Range

-10°C to +150°C (14°F to 302°F)

Optics Transmission Correction

Automatic, based on signals from internal sensors

Reflected apparent temperature correction

Automatic, based on input of reflected temperature

Spot Meter

6.0

Thermal Sensitivity/NETD

<0.10°C @ +30°C (+86°F) / 100mK

Power

External Power Connector Type

Screw Connection (12V/0V/Chassis)

External Power Operation

12/24VDC, 2W continuously / 3.1W absolute max

Voltage Allowed Range

9-36VDC

Storage Media

File Formats

Jpeg + FFF

Image Storage Mode

IR, Visual, MSX

User Interface

Multifunction Displays

Network compatible with Raymarine LightHouse II multifunction displays

Visible Camera

Built-in Digital Camera

640x480

Digital Camera FOV

Adapts to the IR lens

Sensitivity

Minimum 10 Lux without illuminator

 